Remote Control Commands
R&S
®
SGT100A
358
User Manual 1176.8674.02 ─ 07
Return values:
<RMode>
STOP | RUN
RUN
The waveform is output. A trigger event occurred in the triggered
mode.
STOP
The waveform is not output. A trigger event did not occur in the
triggered modes, or waveform output was stopped by the com-
mand
:BB:ARB:TRIG:ARM:EXECute
(armed trigger modes
only).
Example:
BB:ARB:TRIG:SOUR EXT
sets external triggering
BB:ARB:TRIG:MODE ARET
selects the Armed_Retrigger mode.
BB:ARB:TRIG:RMOD?
queries the current status of waveform output.
Response: RUN
the waveform is output, an external trigger was executed.
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SLENgth
<SLength>
The command defines the length of the signal sequence to be output in the Single trig-
ger mode. The unit is defined with command
SOUR:BB:ARB:TRIG:SLUNit
. It is pos-
sible to output deliberately just part of the waveform, an exact sequence of the wave-
form, or a defined number of repetitions of the waveform.
Parameters:
<SLength>
integer
Range:
1 to dynamic
*RST:
1
Default unit: sample
Example:
BB:ARB:SEQ SING
sets trigger mode Single.
BB:ARB:TRIG:SLUN SAMP
sets unit Samples for the entry of sequence length.
BB:ARB:TRIG:SLEN 200
sets a sequence length of 200 samples. The first 200 samples of
the current waveform will be output after the next trigger event.
Manual operation:
See
SOURce Subsystem