Remote control commands
R&S
®
RTO6
1672
User Manual 1801.6687.02 ─ 05
BUS<m>:FORMat
<DataFormat>
Sets the number format for decoded data values of the indicated serial bus. It defines
the format in the decode table, and in the combs of the decoded signal on the screen.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<DataFormat>
HEX | OCT | BIN | ASCII | ASCii | SIGN | USIG
ASCII = ASCii
USIG = unsigned
*RST:
HEX
BUS<m>:NEWList
<FileName>
Loads a label list file.
Suffix:
<m>
.
1..4
Selects the serial bus.
Setting parameters:
<FileName>
String parameter with path and file name.
Example:
BUS1:NEWList 'C:\Protocols\CAN.csv'
BUS1:SYMBols ON
Usage:
Setting only
BUS<m>:SYMBols
<UseTranslation>
Activates the lable list to be used for decoding.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<UseTranslation>
ON | OFF
*RST:
OFF
Usage:
Asynchronous command
BUS<m>:ZCOupling
<ZoomCoupling>
If enabled, the protocol decode zoom and result table are synchronized.
Suffix:
<m>
.
1..4
Protocols