Remote Commands Reference
R&S
®
RTC1000
287
User Manual 1335.7352.02 ─ 04
Suffix:
<b>
.
1, 2
Selects the bus.
<n>
*
Selects the frame.
Return values:
<StartTime>
Range:
depends on sample rate, and time base
Default unit: s
Usage:
Query only
BUS<b>:I2C:FRAMe<n>:ADBStart?
Returns the start time of the address acknowledge bit.
Suffix:
<b>
.
1, 2
Selects the bus.
<n>
Selects the frame.
Return values:
<AckStartTime>
Range:
depends on sample rate, and time base
Default unit: s
Usage:
Query only
BUS<b>:I2C:FRAMe<n>:ACOMplete?
Returns the state of the address.
Suffix:
<b>
.
1, 2
Selects the bus.
<n>
Selects the frame.
Return values:
<AddressComplete> ON | OFF
ON
Address was received completely.
OFF
Address was not received completely.
Usage:
Query only
BUS<b>:I2C:FRAMe<n>:BCOunt?
Returns the number of data bytes of a frame.