Remote Commands Reference
R&S
®
RTC1000
315
User Manual 1335.7352.02 ─ 02
Usage:
Query only
BUS<b>:LIN:FRAMe<n>:VERSion?
Returns the version of the LIN standard for the specified frame.
Suffix:
<b>
.
1, 2
Selects the bus.
<n>
Selects the frame (1...n).
Return values:
<FrameVersion>
V1X | V2X | J2602 | UNK
V1X
LIN version is 1.x
V2X
LIN version is 2.x
J2602
LIN version is J2602
UNK
LIN version is unknown
Usage:
Query only
BUS<b>:LIN:FRAMe<n>:DATA?
Returns the data bytes of the specified frame.
Suffix:
<b>
.
1, 2
Selects the bus.
<n>
Selects the frame (1...n).
Return values:
<FrameData>
Comma-separated list of decimal values of the data bytes.
Usage:
Query only
BUS<b>:LIN:FRAMe<n>:IDSTate?
Returns the identifier state of the selected frame.
Suffix:
<b>
.
1, 2
Selects the bus.
<n>
Selects the frame (1...n).
Protocol Analysis