WGENerator:FUNCtion:EXPonential:POLarity
<Polarity>
Sets the polarity of the generator function exponential.
Parameters:
<Polarity>
POSitive | NEGative
WGENerator:FUNCtion:RAMP:POLarity
<Polarity>
Sets the polarity of the generator function ramp.
Parameters:
<Polarity>
POSitive | NEGative
*RST:
NEG
WGENerator:NOISe:ABSolute
<AbsoluteNoise>
Sets the noise of the waveform in volts.
Parameters:
<AbsoluteNoise>
WGENerator:NOISe:RELative
<RelativeNoise>
Sets the noise of the generated waveform in percentage of the amplitude.
Parameters:
<RelativeNoise>
WGENerator:OUTPut:LOAD
<Load>
Select the user load, the load of the DUT at its connection. You can select either a
"50Ω" or a "High-Z" (high input impedance) load.
Parameters:
<Load>
HIGHz | R50
WGENerator:OUTPut[:ENABle]
<OutputEnable>
Enables the function generator and outputs the waveform.
Parameters:
<OutputEnable>
ON | OFF
17.14.1.2
Arbitrary waveform setup
..................................................................................... 782
WGENerator:ARBitrary:RANGe:START
............................................................................782
WGENerator:ARBitrary:RANGe:STOP
............................................................................. 782
.......................................................................................782
Signal generation (option R&S
RTA-B6)