Remote control commands
R&S
®
RTA4000
747
User Manual 1335.7898.02 ─ 08
●
AVG:
average of the long-term measurement results
●
NPEak:
negative peak value of the long-term measurement results
●
PPEak:
positive peak value of the long-term measurement results
●
STDDev:
standard deviation of the long-term measurement results
●
WFMCount:
the number of waveforms used for the displayed results
Return values:
<WaveformCount>
Usage:
Query only
POWer:RIPPle:RESult:MEAN[:ACTual]?
POWer:RIPPle:RESult:MEAN:AVG?
POWer:RIPPle:RESult:MEAN:NPEak?
POWer:RIPPle:RESult:MEAN:PPEak?
POWer:RIPPle:RESult:MEAN:STDDev?
POWer:RIPPle:RESult:MEAN:WFMCount?
Returns the corresponding statistic result for "Mean".
●
[:ACTual]:
current measurement result
●
AVG:
average of the long-term measurement results
●
NPEak:
negative peak value of the long-term measurement results
●
PPEak:
positive peak value of the long-term measurement results
●
STDDev:
standard deviation of the long-term measurement results
●
WFMCount:
the number of waveforms used for the displayed results
Return values:
<WaveformCount>
Usage:
Query only
POWer:RIPPle:RESult:NDCYcle[:ACTual]?
POWer:RIPPle:RESult:NDCYcle:AVG?
POWer:RIPPle:RESult:NDCYcle:NPEak?
POWer:RIPPle:RESult:NDCYcle:PPEak?
POWer:RIPPle:RESult:NDCYcle:STDDev?
POWer:RIPPle:RESult:NDCYcle:WFMCount?
Returns the corresponding statistic result for the negative duty cycle.
●
[:ACTual]:
current measurement result
●
AVG:
average of the long-term measurement results
●
NPEak:
negative peak value of the long-term measurement results
●
PPEak:
positive peak value of the long-term measurement results
●
STDDev:
standard deviation of the long-term measurement results
●
WFMCount:
the number of waveforms used for the displayed results
Power analysis (option R&S