User Manual 1335.7898.02 ─ 08
TSHutdown
: transmitter shutdown.
OTSHutdown
: override transmitter shutdown.
ITERminal
: inhibit terminal flag bit.
OITerminal
: override inhibit terminal flag bit.
RESet
: reset remote terminal.
VECTor
: transmit vector word.
RSYNchronize
: synchronize with data.
TLAStcmmand
: transmit last command word.
BITWord
: transmit BIT word.
STSHutdown
: selected transmitter shutdown.
OSTShutdown
: override selected transmitter shutdown.
*RST:
ANY
TRIGger:A:MILStd:MCODe:VALue
<ModeCode>
Sets the value of the mode code to be triggered on.
Parameters:
<ModeCode>
TRIGger:A:MILStd:MODE
<TriggerMode>
Parameters:
<TriggerMode>
SYNChronization | FRAME | ERRor | COMMand | STATus |
DATA | CDATa
*RST:
SYNC
TRIGger:A:MILStd:RTADdress:CONDition
<Compare>
For the RT address, sets the triggering condition for the comparison of the decoded
value to the defined range.
Parameters:
<Compare>
EQUal | NEQual | GTHan | GEQual | LEQual | LTHan | WITHin |
OUTSide
*RST:
OFF
TRIGger:A:MILStd:RTADdress:MAXimum
<AddressMaximum>
Sets the maximum RT address.
Parameters:
<AddressMaximum> 01X-string
TRIGger:A:MILStd:RTADdress:MINimum
<AddressMinimum>
Sets the minimum RT address.
Serial bus analysis