![R&S RTA4000 Скачать руководство пользователя страница 662](http://html2.mh-extra.com/html/rands/rta4000/rta4000_user-manual_3161987662.webp)
Remote control commands
R&S
®
RTA4000
662
User Manual 1335.7898.02 ─ 08
BUS<b>:LIN:FRAMe<n>:SYSTate?
Returns the state of the sync field for the specified frame.
Suffix:
<b>
.
1..4
<n>
*
Selects the frame (1...n).
Return values:
<SyncFieldState>
OK | ERR | UNDF
ERR: error
UNDF: undefined
Usage:
Query only
BUS<b>:LIN:FRAMe<n>:SYValue?
Returns the value of the synchronization field.
Suffix:
<b>
.
1..4
<n>
*
Selects the frame (1...n).
Return values:
<SyncFieldValue>
Decimal value
Usage:
Query only
BUS<b>:LIN:FRAMe<n>:VERSion?
Returns the version of the LIN standard for the specified frame.
Suffix:
<b>
.
1..4
<n>
*
Selects the frame (1...n).
Return values:
<FrameVersion>
V1X | V2X | UNK
UNK: Unknown
Usage:
Query only
BUS<b>:LIN:FRAMe<n>:BCOunt?
Returns the number of data bytes in the specified frame.
Suffix:
<b>
.
1..4
Serial bus analysis