System Settings
R&S
®
NRX
139
User Manual 1178.5566.02 ─ 05
OUTPut:RECorder<output>:LIMit:UPPer:RATio[:VALue]
OUTPut:RECorder<output>:LIMit:UPPer[:VALue]
Measurement for Limit Output ← I/O 1, I/O 2 tabs
Available if
is set to:
●
"Limit Violation"
●
"Forw Limit Violation"
●
"Refl Limit Violation"
Sets the measurement that is monitored.
Remote command:
Fail Voltage ← I/O 1, I/O 2 tabs
Available if
is set to:
●
"Limit Violation"
●
"Forw Limit Violation"
●
"Refl Limit Violation"
Sets the fail voltage that is output if a measured value causes a limit violation.
"Low"
0
V
"High"
5
V
Remote command:
Trigger Source for Trigger Output ← I/O 1, I/O 2 tabs
Available if
is set to "Trigger Out".
Sets the trigger source.
Remote command:
Impedance for Trigger Input ← I/O 1, I/O 2 tabs
Available if
is set to "Trigger In".
Sets the termination resistance of the external trigger signal that is supplied at the
Trig
In
/
Out
2 connector. Choose a setting that fits the impedance of the trigger source
to minimize reflections on the trigger signals.
12.1.4
Sensor Manager
Access: [System]
> "Connections"
> "Sensor Manager"
Helps you to manage power sensors, for example, if more than 4
power sensors are
connected, or if you want to connect a LAN power sensor.
Connections