Instrument Functions
R&S
®
NGL200
47
User Manual 1178.8736.02 ─ 02.01
Figure 6-10: Over voltage protection dialog
4. Activate the "Enabled" menu item.
The R&S
NGL200 enables the OVP and displays the "Over Voltage Protection
(OVP)" icon on the selected channel status bar information.
5. Set the required level for OVP.
The R&S
NGL200 displays an on-screen keypad to set the value.
6. Confirm value with the unit key (mV or V).
6.3.3
Over Power Protection (OPP)
When the output power is exceeding the limit sets in the respective channels, an alert
is triggered and the affected channels are turned off according to the settings config-
ured in the OPP dialog.
1. Press [Settings] key.
The R&S
NGL200 displays the main menu window.
2. Select the required channel tab to configure OPP.
The R&S
NGL200 displays the selected channel menu.
3. Select "Over Protection Protection (OPP)" menu item.
The R&S
NGL200 displays the "Over Protection Protection (OPP)" dialog.
Protection