5 = Output terminals (one channel with sense for NGL201, NGM201; two channels for NGL202,

NGM202)

6 = USB connector
7 = Power key

Display (1)

The display is a color TFT touch screen. Depending on the instrument model, up
to two channels are shown on the display. The respective measurement settings
and functions are displayed in the individual channel display area. There is a sta-
tus bar in the device level and channel level, showing the device operating mode
and respective channel settings of the instrument.

For a detailed description on-screen layout, see section "Display Overview" in the
User Manual.

Menu control keys (2)

The menu control keys allow you to access the home window, device/channel
menu window and user key in the instrument.

For a detailed description on menu control keys, see section "Menu Controls" in
the User Manual.

Rotary knob and back key (3)

The rotary knob and back key are used for menu navigation and value adjustment
in the instrument.

For a detailed description on rotary knob and back key, see section "Navigation
Controls" in the User Manual.

Output and channel keys (4)

The channel key allows you to select the power supply channel to source or sink
power. The output key allows you to enable or disable the output power on the
channel key.

Refer to datasheet for the channel voltage/current limits in the source and sink
mode.

Output terminals (5)

Depending on the instrument type, one or two output channels are available to
source or sink power.

Overview of Controls

Содержание NGL200 series

Страница 1: ...R S NGL200 NGM200 Power Supply Series Getting Started Getting Started Version 04 1178872002 D2...

Страница 2: ...2019 Rohde Schwarz GmbH Co KG M hldorfstr 15 81671 M nchen Germany Phone 49 89 41 29 0 Fax 49 89 41 29 12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data withou...

Страница 3: ...ic Safety Instructions and the product documentation in a safe place and pass them on to the subsequent users Riesgo de lesiones y da os en el instrumento El instrumento se debe usar de manera adecuad...

Страница 4: ...die Produktdokumentation gut auf und geben Sie diese an weitere Benutzer des Produkts weiter Risque de blessures et d endommagement de l appareil L appareil doit tre utilis conform ment aux prescript...

Страница 5: ...ument up to date and to be informed about new application notes related to your instrument please send an e mail to the Customer Support Center stating your instrument and your wish We will take care...

Страница 6: ...3 3 Unpacking and Checking the Instrument 13 3 4 Setting Up the Instrument 14 3 4 1 Bench Operation 14 3 4 2 Rack Mounting 15 4 Instrument Tour 16 4 1 Overview of Controls 16 4 1 1 Front Panel 16 4 1...

Страница 7: ...Contents R S NGL200 NGM200 4 Getting Started 1178 8720 02 04...

Страница 8: ...ssages and information on maintenance The online version html format of the user manual provides the complete con tents for immediate display on the internet Basic safety instructions Contains safety...

Страница 9: ...ues of the cur rent firmware version and describe the firmware installation The open source acknowledgment document provides verbatim license texts of the used open source software See www rohde schwa...

Страница 10: ...ith overtemperature protection OTP This safety feature protects the R S NGL NGM from overheating When the temperature in the power supply exceeds the OTP limit the channel outputs are automatically cu...

Страница 11: ...Welcome to R S NGL NGM R S NGL200 NGM200 8 Getting Started 1178 8720 02 04 http www rohde schwarz com product ngl200 for R S NGL and http www rohde schwarz com product ngm200 for R S NGM...

Страница 12: ...e instrument casing Read and observe the Basic Safety Instructions delivered as a printed brochure with the instrument Note that the basic safety instructions also contain information on operating con...

Страница 13: ...ment results Electromagnetic interference EMI may affect the measurement results To suppress the generated EMI Use suitable shielded cables of high quality for example LAN cables Note the EMC classifi...

Страница 14: ...ed that a safe operation is no longer possible the instrument must be shut down and secured against any unintended operation Safe operation can no longer be assumed when Instrument shows visible damag...

Страница 15: ...rer without the product s ventilation being obstructed If the manufacturer s specifications are not observed this can result in electric shock fire and or serious personal injury and in some cases dea...

Страница 16: ...15 87 lb R S NGL202 R S NGM202 7 3 kg 16 09 lb 7 4 kg 16 31 lb 3 3 Unpacking and Checking the Instrument Unpack the R S NGL NGM power supply carefully and check the content of the package Check the eq...

Страница 17: ...instru ment in antistatic wrap to protect it from electrostatic charging Secure the instrument to prevent any movement and other mechanical effects during transportation Delivery package The package...

Страница 18: ...3 4 2 Rack Mounting The instrument can be installed in a 19 rack using the rack adapter R S HZN96 P N 3638 7813 02 Proceed according to the installation instructions supplied with the rack adapter Amb...

Страница 19: ...s 4 1 1 Front Panel The front panel of the R S NGL NGM is as shown in Figure 4 1 The function keys and navigation controls are located beside the display The various connec tors are located at the rig...

Страница 20: ...l keys 2 The menu control keys allow you to access the home window device channel menu window and user key in the instrument For a detailed description on menu control keys see section Menu Controls i...

Страница 21: ...screen shots Power key 7 The Power key switches the instrument on and off 4 1 2 Rear Panel Figure 4 2 shows the rear panel of the R S NGL NGM with its connectors Figure 4 2 Rear panel of R S NGL NGM...

Страница 22: ...connectors 9 10 Output terminals Either the output terminals at the front panel or those at the back panel can be used Using both terminals at the same time can cause instrument mal function Digital v...

Страница 23: ...O connector 15 The Digital I O option R S NGL K103 or R S NGM K103 must be installed for this function to be available in the instrument The specified voltages are 0 V to 24 V for all output pins and...

Страница 24: ...hure and safety measures in previous sections are observed Also check if the value on the voltage selector corresponds to the mains voltage 100 V 115 V or 230 V Fuse rating The R S NGL NGM uses the sa...

Страница 25: ...utput channels are turned off when the instrument is switched on to prevent connected loads from being damaged unintentionally During startup the R S NGL NGM is loaded with the last saved instrument s...

Страница 26: ...t menu see section Out put mode in the User Manual On the display sink mode is shown as negative current 5 1 Setting the Output Voltage and Current 1 Press Home key The R S NGL NGM displays the home w...

Страница 27: ...e the same as in source mode green if the current flowing into the R S NGL NGM is below the set current and red if the current is limited to the set value The only visible indication of sink mode is t...

Страница 28: ...strument damage caused by cleaning agents Use a dry lint free cloth to clean the product When cleaning keep in mind that the casing is not waterproof Do not use any liquids for cleaning Cleaning agent...

Страница 29: ...t 6 Overview of controls Front panel 16 Rear panel 18 P Putting into operation 9 Intended operation 12 Safety 10 Unpacking and checking the instrument 13 R Rear panel AC inlet with fuse holder 19 Chan...

Отзывы: