M3SR Series 4100
Selecting the Scan Rate
4.24
Operating Manual 6175.4760.02 – 01
4.3.5.9
Selecting the Scan Rate
Softkey
Type
Description
Listbox
1.
Press 'Mode' softkey.
2.
Select desired scan rate from listbox with
the knob.
3.
Press 'ENT' to confirm.
Possible values:
•
fix
•
scan 2
•
scan 5
When selecting ‘fix’, the ALE does not deter-
mine the best link setup frequency anymore,
instead the user has to select the active chan-
nel, using the softkey ‘Channel’.
‘scan 5’ means 5 frequency changes per sec-
ond, the maximum possible scan speed in
ALE networks. It allows the fastest Link Set-
ups- but is still slower than the fast link setup
(FLSU) of ALE-3G.
‘scan 2’ means 2 frequency changes per sec-
ond and even longer lifetime of electrome-
chanical ATU and R&S FK4120 / R&S FK4140
components, but the link setup is slower by
factor 2.5.
Содержание M3SR 4100 Series
Страница 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Страница 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Страница 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Страница 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Страница 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Страница 546: ...M3SR Series 4100 Further Settings are Relevant for SECOM H Operation 4 210 Operating Manual 6175 4760 02 01...
Страница 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Страница 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Страница 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...