M3SR Series 4100
Selecting the Signal Squelch Subtone Frequency
3.206
Operating Manual 6175.4760.02 – 01
3.9.4.3
Selecting the Signal Squelch Subtone Frequency
Softkey
Softkey Type
Description
Listbox
1.
Press 'SQL Tone' softkey.
2.
Select desired frequency from listbox.
3.
Press 'ENT' to confirm.
Possible values (in Hz):
67 - 69.3 - 71.9 - 74.4 - 77 - 79.7 - 82.5 - 85.4
- 88.5 - 91.5 - 94.8 - 97.4 - 100 - 103.5 - 107.2
- 110.9 - 114.8 - 118.8 - 123 - 127.3 - 131.8 -
136.5 - 141.3 - 146.2 - 151.4 - 156.7 - 162.2 -
167.9 - 173.8 - 179.9 - 186.2 - 192.8 - 203.5 -
210.7 - 218.1 - 225.7 - 233.6 - 241.8 - 250.3
Default value:
100 Hz
The signal squelch is supported in modulation
modes F3E, H3E and A3E.
When enabled, the audio signal is unmuted
only in case of reception of the predefined sig-
nal tone. On the other hand, the transmitter su-
perimposes that signal tone frequency as well.
The subtones within a network should be set
to identical values.
Содержание M3SR 4100 Series
Страница 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Страница 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Страница 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Страница 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Страница 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Страница 546: ...M3SR Series 4100 Further Settings are Relevant for SECOM H Operation 4 210 Operating Manual 6175 4760 02 01...
Страница 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Страница 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Страница 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...