M3SR Series 4100
Changing the Squelch Hangover Time
3.178
Operating Manual 6175.4760.02 – 01
3.7.3.8
Changing the Squelch Hangover Time
Softkey
Softkey Type
Description
Listbox
The hangover time is the time where the audio
signal remains unmuted after the RF signal
disappeared. To change the hangover time for
the selected squelch type:
1.
Press 'SQL HANG' softkey.
2.
Select desired value from listbox.
3.
Press 'ENT' to confirm.
The new selection is now effective. When the
desired squelch type is selected, the squelch
hangover time will become automatically acti-
vated.
Possible values:
SHORT (300 ms) - MEDIUM (600 ms) -
LONG (900 ms)
Default value:
MEDIUM