Operating Manual 6175.4760.02 – 01
3.177
M3SR Series 4100
Changing the Default Release Times
3.7.3.7
Changing the Default Release Times
Softkey
Softkey Type
Description
Listbox
1.
Press desired 'R-Time' softkey.
2.
Select desired time value from listbox.
3.
Press 'ENT' to confirm.
Possible values (in ms):
25 - 150 - 500 - 1000 - 3000 - 5000 - 9000
See also 'Release Time' softkey in the Fixed
Frequency Operational menu 1.
By means of the softkeys 'R-Time .. A1A, A3E,
J3E, J2D, B8E' the operator can change and
store the default release times for several
modulation modes. E.g. if modulation mode
A1A is selected in operational menu, the new
default A1A release time will be loaded.
The release time (= hold time + decay time) is
the time after which the AGC is achieving the
full receiver sensitivity.
Avoid faster release times for voice operation,
it would sound too jittery.
Содержание M3SR 4100 Series
Страница 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Страница 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Страница 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Страница 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Страница 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Страница 546: ...M3SR Series 4100 Further Settings are Relevant for SECOM H Operation 4 210 Operating Manual 6175 4760 02 01...
Страница 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Страница 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Страница 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...