General Instrument Setup
R&S
®
FSW
692
User Manual 1173.9411.02 ─ 43
........................................................................................ 694
.................................................................................................695
........................................................................................695
Frequency Response File Information
........................................................................ 695
Remove Frequency Response File
.............................................................................696
.............................................................................................698
State
Enables or disables the general usage of user-defined frequency response correction
settings. If activated, the data in the active correction files is combined to create a filter.
This filter is applied to the measurement results of subsequent sweeps.
Remote command:
[SENSe:]CORRection:FRESponse<si>:USER:STATe
Testing the validity of the correction setting:
[SENSe:]CORRection:FRESponse<si>:USER:VALid?
Ext. PA Correction
This function is only available if an external preamplifier is connected to the R&S
FSW,
and only for frequencies above 1
GHz. For details on connection, see the preamplifier's
documentation.
Using an external preamplifier, you can measure signals from devices under test with
low output power, using measurement devices which feature a low sensitivity and do
not have a built-in RF preamplifier.
When you connect the external preamplifier, the R&S
FSW reads out the touchdown
(
.S2P
) file from the EEPROM of the preamplifier. This file contains the s-parameters of
the preamplifier. As soon as you connect the preamplifier to the R&S
FSW, the pream-
plifier is permanently on and ready to use. However, you must enable data correction
based on the stored data explicitly on the R&S
FSW using this setting.
When enabled, the R&S
FSW automatically compensates the magnitude and phase
characteristics of the external preamplifier in the measurement results. Any internal
preamplifier, if available, is disabled.