Remote Commands
R&S
®
FSW
1306
User Manual 1173.9411.02 ─ 43
SYSTem:FORMat:IDENt
<IDNFormat>
This command selects the response format to the
Parameters:
<IDNFormat>
LEGacy
Format is compatible to R&S FSP/FSU/FSQ/FSG family.
NEW | FSL
R&S
FSW format
Format is also compatible to the R&S FSL and R&S FSV family
*RST:
not reset!
Example:
SYST:FORM:IDEN LEG
Adapts the return value of *IDN? to the R&S FSP/FSU/FSQ fam-
ily.
Manual operation:
See
SYSTem:PRESet:COMPatible
<OpMode>
This command defines the operating mode that is activated when you switch on the
R&S
FSW or press the [PRESET] key.
For details on operating modes see
Chapter 6, "Applications, Measurement Channels,
Parameters:
<OpMode>
SANalyzer
(Default:)
Defines Signal and Spectrum Analyzer operating mode as the
presetting.
MSRA
Defines Multi-Standard Radio Analysis (MSRA) as the preset
default operating mode.
RTSM
Defines Multi-Standard Real-Time (MSRT) as the preset default
operating mode.
Manual operation:
See
SYSTem:SECurity[:STATe]
<State>
Activates or queries secure user mode.
Note:
Before you activate secure user mode, store any instrument settings that are
required beyond the current session, such as predefined instrument settings, trans-
ducer files, or self-alignment data.
Note:
Initially after installation of the R&S
FSW-K33 option, secure user mode must be
enabled manually once before remote control is possible. This is necessary to prompt
for a change of passwords.