Remote Commands to Perform Measurements with I/Q Data
R&S
®
FSV/A3000 I/Q
Analyzer
247
User Manual 1178.8536.02 ─ 01
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MAXimum:ABOVe
................................. 248
CALCulate<n>:DELTamarker<m>:SGRam:Y:MAXimum:BELow
..........................................249
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MAXimum:BELow
................................. 249
CALCulate<n>:DELTamarker<m>:SGRam:Y:MAXimum:NEXT
........................................... 249
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MAXimum:NEXT
...................................249
CALCulate<n>:DELTamarker<m>:SGRam:Y:MAXimum[:PEAK]
..........................................249
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MAXimum[:PEAK]
................................. 249
CALCulate<n>:DELTamarker<m>:SGRam:Y:MINimum:ABOVe
.......................................... 249
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MINimum:ABOVe
.................................. 249
CALCulate<n>:DELTamarker<m>:SGRam:Y:MINimum:BELow
...........................................250
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MINimum:BELow
.................................. 250
CALCulate<n>:DELTamarker<m>:SGRam:Y:MINimum:NEXT
............................................ 250
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MINimum:NEXT
.................................... 250
CALCulate<n>:DELTamarker<m>:SGRam:Y:MINimum[:PEAK]
...........................................250
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MINimum[:PEAK]
.................................. 250
CALCulate<n>:DELTamarker<m>:SGRam:FRAMe
<Frame>
CALCulate<n>:DELTamarker<m>:SPECtrogram:FRAMe
<Frame>
This command positions a delta marker on a particular frame. The frame is relative to
the position of marker 1.
The command is available for the spectrogram.
Suffix:
<n>
.
<m>
Parameters:
<Frame>
Selects a frame either by its frame number or time stamp.
The frame number is available if the time stamp is off. The range
depends on the history depth.
The time stamp is available if the time stamp is on. The number
is the distance to frame 0 in seconds. The range depends on the
history depth.
Default unit: S
Example:
CALC:DELT4:SGR:FRAM -20
Sets fourth deltamarker 20 frames below marker 1.
CALC:DELT4:SGR:FRAM 2 s
Sets fourth deltamarker 2 seconds above the position of marker
1.
Manual operation:
See
I/Q Analysis