Remote Commands for Bluetooth Measurements (K8)
R&S
®
FSV-K8
79
Operating Manual 1176.7610.02 ─ 02
Example:
For the first steps refer to
chapter 4.14, "Programming Exam-
CONF:BTO:MEAS IBS
Activates the In–band Spurious Emissions measurement.
CONF:BTO:CHAN 7
Adjust the TX channel number.
INIT;*WAI
Starts the measurement with synchronization.
CALC:BTO:IBS:TXR?
Reads the TX channel reference power.
Usage:
Query only
Mode:
BT
CALCulate<n>:BTOoth:ICFTolerance?
<Mode>
This command determines the Initial Carrier Frequency Tolerance.
Note:
This command is only available with active Modulation Characteristics measurement
(see
on page 96). With all other measure-
ments this command causes a query error.
Suffix:
<n>
.
irrelevant
Parameters:
<Mode>
MINimum | MAXimum | AVERage
*RST:
-
Example:
For the first steps refer to
chapter 4.14, "Programming Exam-
CONF:BTO:MEAS ICFT
Activates the Initial Carrier Frequency Tolerance measurement.
CONF:BTO:SWE:COUN 20
Initiates the sweep counter with 20.
INIT;*WAI
Starts the measurement with synchronization.
CALC:BTO:ICFT? AVER
Queries the average value.
Usage:
Query only
Mode:
BT
Manual operation:
See
CALCulate<n>:BTOoth:MCHar:DF<Delta>:AVERage?
<Type>
This command determines the average frequency deviation for varying bit patterns of
the payload.
CALCulate subsystem