Instrument Functions for Bluetooth Measurements (K8)
R&S
®
FSV-K8
60
Operating Manual 1176.7610.02 ─ 02
3.9 Softkeys of the Trigger Menu (Option R&S
FSV-K8)
The following table shows all softkeys available in the "Trigger" menu in Bluetooth
mode (TRIG key). It is possible that your instrument configuration does not provide all
softkeys. If a softkey is only available with a special option, model or (measurement)
mode, this information is delivered in the corresponding softkey description.
Trg/Gate Source
Opens the "Trigger/Gate Source" dialog box to select the trigger/gate mode.
The default setting is "Free Run". If a trigger mode other than "Free Run" has been set,
the enhancement label "TRG" is displayed and the trigger source is indicated.
Remote command:
Free Run ← Trg/Gate Source
The start of a sweep is not triggered. Once a measurement is completed, another is
started immediately.
Remote command:
TRIG:SOUR IMM
, see
External ← Trg/Gate Source
Defines triggering via a TTL signal at the "EXT TRIG/GATE IN" input connector on the
rear panel.
Remote command:
TRIG:SOUR EXT
, see
Video ← Trg/Gate Source
Defines triggering by the displayed voltage.
A horizontal trigger line is shown in the diagram. It is used to set the trigger threshold
from 0 % to 100 % of the diagram height.
Video mode is only available in the time domain.
Remote command:
TRIG:SOUR VID
, see
RF Power ← Trg/Gate Source
Defines triggering of the measurement via signals which are outside the measurement
channel.
This trigger mode is available with detector board 1307.9554.02 Rev 05.00 or higher. It
is not available for input from the R&S Digital I/Q Interface (option R&S
FSV-B17). If
RF Power trigger mode is selected and digital baseband input is activated, the trigger
mode is automatically switched to "Free Run".
In RF Power trigger mode the instrument uses a level detector at the first intermediate
frequency. The detector threshold can be selected in a range between - 50
dBm and
-10
dBm at the input mixer. The resulting trigger level at the RF input lies within the
following range:
Softkeys of the Trigger Menu (Option R&S
FSV-K8)