Instrument Functions for Vector Signal Analysis
R&S
®
FSV-K70
86
Operating Manual 1176.7578.02 ─ 09
Figure 3-13: Result display "Magnitude Error" in normal mode
Available for source types:
●
Modulation Errors
SCPI commands:
CALC:FEED 'XTIM:DDEM:ERR:MPH'
to define the required source type (see
CALC:FORM MAGN
to define the result type (see
TRAC:DATA TRACE1
to query the trace results (see
3.1.1.19
Phase Error
Displays the phase error of the measuremente signal with respect to the reference sig-
nal as a function of symbols over time.
t
PHASE
t
PHASE
t
ERR
PHASE
REF
MEAS
_
with t=n
·
T
D
and T
D
=the duration of one sampling period at the sample rate defined by
the display points per symbol parameter (see
Measurement Result Display