Remote Control Commands - R&S
FSV-K70
R&S
®
FSV-K70
232
Operating Manual 1176.7578.02 ─ 09
Mode:
VSA
CALCulate<n>:MARKer<m>:FUNCtion:DDEMod:STATistic:PERRor?
<type>
This command queries the results of the phase error measurement performed for digi-
tal demodulation.
Suffix:
<n>
.
1..4
screen number
<m>
1..4
irrelevant
Query parameters:
<type>
<none>
Phase error in degree
AVG
RMS phase error value (over several sweeps)
RPE
Peak value of phase error (over several sweeps)
SDEV
Standard deviation of phase error values over several sweeps
PCTL
95% percentile of RMS value (over several sweeps)
PEAK
Maximum phase error of current sweep
PAVG
Average of maximum phase error values over several sweeps
TPE
Maximum phase error over several sweeps
PSD
Standard deviation of maximum phase error values over several
sweeps
PPCT
95% percentile of maximum RMS values over several sweeps
*RST:
PEAK
Usage:
Query only
Mode:
VSA
CALCulate<n>:MARKer<m>:FUNCtion:DDEMod:STATistic:QERRor?
<type>
This command queries the results of the Quadratur error measurement performed for
digital demodulation.