Remote Control Commands - R&S
FSV-K70
R&S
®
FSV-K70
219
Operating Manual 1176.7578.02 ─ 09
CALCulate<n>:LIMit:MACCuracy:FERRor:PCURrent:VALue
<LimitValue>
CALCulate<n>:LIMit:MACCuracy:FERRor:PMEan:VALue
<LimitValue>
CALCulate<n>:LIMit:MACCuracy:FERRor:PPEak:VALue
<LimitValue>
CALCulate<n>:LIMit:MACCuracy:FERRor:RCURrent:VALue
<LimitValue>
CALCulate<n>:LIMit:MACCuracy:FERRor:RMEan:VALue
<LimitValue>
CALCulate<n>:LIMit:MACCuracy:FERRor:RPEak:VALue
<LimitValue>
This command defines the value for the current, peak or mean frequency error (peak
or RMS) limit. Note that the limits for the current and the peak value are always kept
identical.
This command is available for FSK modulation only.
Suffix:
<n>
.
1..4
window
Setting parameters:
<LimitValue>
numeric value
the value x (x>0) defines the interval [-x; x]
Range:
0.0 to 100
*RST:
1.5 (mean: 1.0)
Default unit: Hz
Example:
CALC2:FEED 'XTIM:DDEM:MACC'
switch on result summary in screen 2
CALC2:LIM:MACC:FERR:RPE:VAL 15
define a limit of [-15;15] Hz
Mode:
VSA
CALCulate<n>:LIMit:MACCuracy:MERRor:PCURrent:VALue
<LimitValue>
CALCulate<n>:LIMit:MACCuracy:MERRor:PMEan:VALue
<LimitValue>
CALCulate<n>:LIMit:MACCuracy:MERRor:PPEak:VALue
<LimitValue>
CALCulate<n>:LIMit:MACCuracy:MERRor:RCURrent:VALue
<LimitValue>
CALCulate<n>:LIMit:MACCuracy:MERRor:RMEan:VALue
<LimitValue>
CALCulate<n>:LIMit:MACCuracy:MERRor:RPEak:VALue
<LimitValue>
This command defines the value for the current, peak or mean magnitude error (peak
or RMS) limit. Note that the limits for the current and the peak value are always kept
identical.
Suffix:
<n>
.
1..4
window
Setting parameters:
<LimitValue>
numeric value
the value x (x>0) defines the interval [-x; x]
Range:
0.0 to 100
*RST:
1.5
Default unit: %
CALCulate subsystem
Содержание FSV-K70
Страница 368: ...Formulae and Abbreviations R S FSV K70 368 Operating Manual 1176 7578 02 09 Formulae ...
Страница 370: ...Formulae and Abbreviations R S FSV K70 370 Operating Manual 1176 7578 02 09 Formulae ...
Страница 371: ...Formulae and Abbreviations R S FSV K70 371 Operating Manual 1176 7578 02 09 Formulae ...
Страница 372: ...Formulae and Abbreviations R S FSV K70 372 Operating Manual 1176 7578 02 09 Formulae ...