Analog Demodulation Option R&S
FSV–K7
R&S
®
FSV-K7/K7S
151
Operating Manual 1176.7561.02 ─ 06
Example:
FILT:DEMP ON
Activates the selected deemphasis.
Mode:
ADEMOD
Manual operation:
See
[SENSe:]FILTer<n>:DEMPhasis:TCONstant
<Deemphasis>
This command selects the deemphasis in the specified window.
For details on deemphasis refer to
For details on the demodulation bandwidth range refer to
Suffix:
<n>
.
1...4
window
Parameters:
<Deemphasis>
25 us | 50 us | 75 us | 750 us
*RST:
50 us
Example:
FILT:DEMP:TCON 750us
Selects the deemphasis for the demodulation bandwidth range
from 800 Hz to 4 MHz with a time constant of 750 µs.
Mode:
ADEMOD
Manual operation:
See
[SENSe:]FILTer<n>:HPASs[:STATe]
<State>
This command activates/deactivates the selected high pass filter in the specified win-
dow.
For details on the high pass filter refer to
Suffix:
<n>
.
1...4
window
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
FILT:HPAS ON
Activates the selected high pass filter.
Mode:
ADEMOD
Manual operation:
See
See
Remote Commands of the Analog Demodulation (R&S
FSV–K7)