![R&S FSMR3000 Скачать руководство пользователя страница 473](http://html2.mh-extra.com/html/rands/fsmr3000/fsmr3000_user-manual_3152698473.webp)
Remote Commands
R&S
®
FSMR3000
473
User Manual 1179.0116.02 ─ 02
, this command does not reset traces in
maxhold, minhold or average mode. Therefore it can be used to continue measure-
ments using maxhold or averaging functions.
Suffix:
<n>
.
irrelevant
Example:
INIT:CONT OFF
Switches to single measurement mode.
DISP:WIND:TRAC:MODE AVER
Switches on trace averaging.
SWE:COUN 20
Setting the measurement counter to 20 measurements.
INIT;*WAI
Starts the measurement and waits for the end of the 20 mea-
surements.
INIT:CONM;*WAI
Continues the measurement (next 20 measurements) and waits
for the end.
Result: Averaging is performed over 40 measurements.
INITiate<n>:CONTinuous
<State>
This command controls the measurement mode for an individual channel.
Note that in single measurement mode, you can synchronize to the end of the mea-
surement with *OPC, *OPC? or *WAI. In continuous measurement mode, synchroniza-
tion to the end of the measurement is not possible. Thus, it is not recommended that
you use continuous measurement mode in remote control, as results like trace data or
markers are only valid after a single measurement end synchronization.
For details on synchronization see
.
Suffix:
<n>
.
irrelevant
Parameters:
<State>
ON | OFF | 0 | 1
ON | 1
Continuous measurement
OFF | 0
Single measurement
*RST:
1
Example:
INIT:CONT OFF
Switches the measurement mode to single measurement.
INIT:CONT ON
Switches the measurement mode to continuous measurement.
Manual operation:
See
Configuring the Measurement