R&S ESU
Basic Operation
Setting Parameters
4.8
Quick Start Guide 1302.6163.62 - 04
4.2.2 The Rotary Knob and Arrow Keys
The rotary knob and arrow keys are located next to the keypad.
4.2.3 Editing Numeric Parameters
Numeric values are always entered in a data entry field that automatically appears after the
parameter is selected.
The title line shows the name of the instrument parameter that was selected. The entry is
performed in the editing line. After the entry field is opened, it will contain the currently valid
parameter value and its unit. The optional third and fourth lines show status and error
messages which always refer to the current entry.
With frequency entries, the
ENTER
key corresponds to the
Hz
key.
With time data, it corresponds to the µs (kHz) key.
The rotary knob has several functions:
• Increments (clockwise direction) or decrements (counterclockwise
direction) the instrument parameter at a defined step width in the case
of a numeric entry.
• Shifts the selection bar horizontally or vertically within tables as long as
an entry field is not open. The arrow keys are used to change the
direction of motion (horizontal/vertical).
• Selects the individual letters when the alphanumeric editor is used.
• Shifts markers, limit lines, etc. on the screen.
• When it is pressed, it concludes an entry.
Within a table, the arrow keys move the selection bar to the desired
position.
Within the alphanumeric editor, the
U
l
or
U
r
arrow keys move the cursor
to the desired position.
The
U
u
or
U
d
arrow keys do the following:
• Increase or decrease the instrument parameter in the case of numeric
entries.
• Switch between the editing line and the character selection in the case
of alphanumeric entries.
Title line with parameter designation
Editing line with parameter value and unit
Status and error messages
Содержание esu
Страница 1: ...R S ESU EMI Test Receiver Quick Start Guide Quick Start Guide Test Measurement 1302 6163 62 04 ...
Страница 26: ...R S ESU Contents 6 Quick Start Guide 1302 6163 62 04 ...
Страница 28: ......
Страница 32: ...R S ESU 0 4 Quick Start Guide 1302 6163 62 04 ...
Страница 88: ...R S ESU Preparing for Use Operating System Properties 2 38 Quick Start Guide 1302 6163 62 04 ...
Страница 104: ...R S ESU Basic Operation Setting Parameters 4 12 Quick Start Guide 1302 6163 62 04 ...
Страница 175: ...Quick Start Guide 1302 6163 62 04 6 33 R S ESU LAN Interface Manual Operation of the R S ESU with XP Remote Desktop ...
Страница 178: ...R S ESU LAN Interface Manual Operation of the R S ESU with XP Remote Desktop 6 36 Quick Start Guide 1302 6163 62 04 ...
Страница 201: ...Quick Start Guide 1302 6163 62 04 R S ESU Appendix Appendix ...
Страница 202: ...Quick Start Guide 1302 6163 62 04 R S ESU Appendix ...