Operating Manual 1302.6163.12 - 03
4.281
R&S ESU
Instrument Functions
Basic Settings
➢
The following instrument settings will then be changed:
Remote command:
SYST:LANG "SCPI" | "8560E" |
"8561E" | "8562E" | "8563E" |
"8564E" | "8565E" | "8566A" |
"8566B" | "8568A" | "8568A_DC" |
"8568B" | "8568B_DC" | "8591E" |
"8594E" | "71100C" | "71200C" |
"71209A"
IF GAIN NORM/
PULS
The
IF GAIN NORM/PULS
softkey configures the internal IF gain settings in HP
emulation mode due to the application needs. This setting is only taken into account
for resolution bandwidth < 300 kHz.
This softkey is only available, if a HP languge is selected via the
softkey.
Remote command:
SYST:IFG:MODE PULS
SWEEP REP
ON/OFF
The
SWEEP REP ON/OFF
softkey controls a repeated sweep of the
E1
and
MKPK
HI
HP model commands (for details on the commands refer to
HP Models 856xE, 8566A/B, 8568A/B and 8594E” on page 6.263
). If the repeated
sweep is OFF, the marker is set without sweeping before.
Model
# of Trace
Points
Start Freq.
Stop Freq.
Ref Level
Input
Coupling
8566A/B
1001
2 GHz
22 GHz
0 dBm
DC
8568A/B
1001
0 Hz
1.5 GHz
0 dBm
AC
8560E
601
0 Hz
2.9 GHz
0 dBm
AC
8561E
601
0 Hz
6.5 GHz
0 dBm
AC
8562E
601
0 Hz
13.2 GHz
0 dBm
AC
8563E
601
0 Hz
26.5 GHz
0 dBm
AC
8564E
601
0 Hz
40 GHz
0 dBm
AC
8565E
601
0 Hz
50 GHz
0 dBm
AC
8594E
401
0 Hz
3 GHz
0 dBm
AC
Notes regarding switch over to 8566A/B and 8568A/B on R&S FSUP
• The stop frequency indicated in the table may be limited to the corresponding
frequency of the R&S ESU, if required.
NORM
Optimized for high dynamic range,
overload limit is close to reference level.
PULS
Optimized for pulsed signals,
overload limit up to 10 dB above reference level.
In single sweep mode, switch off this softkey before you set the marker via the
E1
and
MKPK HI
commands in order to avoid sweeping afresh.
Содержание ESU Series
Страница 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual...
Страница 25: ......
Страница 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03...
Страница 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03...
Страница 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03...
Страница 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03...
Страница 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03...
Страница 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03...
Страница 821: ...R S ESU Remote Control Programming Examples More Complex Programming Examples 7 32 Operating Manual 1302 6163 12 03...
Страница 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03...
Страница 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU...
Страница 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03...