Sample Application
R&S
®
DVMS1
36
Getting Started 2113.7619.02 ─ 12
Every second, "Bite Rate - TS bit rate higher than specified limit" log entries are
inserted at the end of the log. In addition, the "Bit Rate" statistics counter is incre-
mented every second. Also, under "INPUT", a red LED symbol at the selected
input indicates an active monitoring fault.
8. To simplify the monitoring log, click "Log Type" and then select "Transition" to
change the log type.
Only at the moment when the monitoring error is detected, one single entry is
inserted. As long as the error is present, no new log entries are added, but the
"Statistics Counter" is incremented. When the monitoring error disappears, a new
log entry is inserted informing you that the error has disappeared and how long the
error has lasted.
For further details, see the user manual or help system.
9. Stop reporting the monitoring faults by deactivating the TS bit rate monitoring:
a) In the toolbar, select "Monitoring Configuration".
b) Select the "Extended Checks I" tab.
c) In the second line, deactivate the "TS" option for TS bit rate monitoring.
10. Click "OK" to close the configuration dialog.
11. Click "Control" and select "Clear Statistics & Log".
6.5.4
Checking the Content of the PSI Table PAT
PAT is used as abbreviation for program association table as specified in the associ-
ated MPEG2 standard ISO/IEC13818
‑
1.
Performing the Measurement