![R&S CMW-KM5 Series Скачать руководство пользователя страница 721](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802721.webp)
LTE Multi Evaluation Measurement
R&S
®
CMW-KM5xx/-KS5xx
721
User Manual 1173.9628.02 ─ 16
Options:
R&S CMW-KM012
FETCh:LTE:MEAS<i>:MEValuation:LIST:SEMask:OBW:CURRent?
FETCh:LTE:MEAS<i>:MEValuation:LIST:SEMask:OBW:AVERage?
FETCh:LTE:MEAS<i>:MEValuation:LIST:SEMask:OBW:EXTReme?
FETCh:LTE:MEAS<i>:MEValuation:LIST:SEMask:OBW:SDEViation?
CALCulate:LTE:MEAS<i>:MEValuation:LIST:SEMask:OBW:CURRent?
CALCulate:LTE:MEAS<i>:MEValuation:LIST:SEMask:OBW:AVERage?
CALCulate:LTE:MEAS<i>:MEValuation:LIST:SEMask:OBW:EXTReme?
Return the occupied bandwidth for all measured list mode segments.
The values described below are returned by
FETCh
commands.
CALCulate
com-
mands return limit check results instead, one value for each result listed below.
Return values:
<Reliability>
<OBW>
Comma separated list of values, one per measured segment
Range:
0 MHz to 40 MHz
Default unit: Hz
Example:
See
Usage:
Query only
Firmware/Software:
V2.1.30
Options:
R&S CMW-KM012
FETCh:LTE:MEAS<i>:MEValuation:LIST:SEMask:TXPower:CURRent?
FETCh:LTE:MEAS<i>:MEValuation:LIST:SEMask:TXPower:AVERage?
FETCh:LTE:MEAS<i>:MEValuation:LIST:SEMask:TXPower:MINimum?
FETCh:LTE:MEAS<i>:MEValuation:LIST:SEMask:TXPower:MAXimum?
FETCh:LTE:MEAS<i>:MEValuation:LIST:SEMask:TXPower:SDEViation?
CALCulate:LTE:MEAS<i>:MEValuation:LIST:SEMask:TXPower:CURRent?
CALCulate:LTE:MEAS<i>:MEValuation:LIST:SEMask:TXPower:AVERage?
CALCulate:LTE:MEAS<i>:MEValuation:LIST:SEMask:TXPower:MINimum?
CALCulate:LTE:MEAS<i>:MEValuation:LIST:SEMask:TXPower:MAXimum?
Return the total TX power in the slot for all measured list mode segments.
The values described below are returned by
FETCh
commands.
CALCulate
com-
mands return limit check results instead, one value for each result listed below.
Return values:
<Reliability>
<TXpower>
Comma separated list of values, one per measured segment
Range:
-100 dBm to 55 dBm
Default unit: dBm
Example:
See
Usage:
Query only
Command Reference