![R&S CMW-KM5 Series Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802057.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
57
User Manual 1173.9628.02 ─ 16
If the UE does not use the granted uplink resources for transmission, the allocation
expires after some unused subframes (implicit release). In that case, a new grant is
sent automatically to the UE.
SPS is only supported for the PCC, not for SCCs. HARQ can not be combined with
SPS. Connected DRX is supported, but without UL dynamic scheduling.
2.2.16 Operating Bands
The carrier frequencies for LTE signals are defined in 3GPP TS 36.101. Each operat-
ing band contains a number of carrier frequencies identified by channel numbers
(EARFCN, E-UTRA Absolute Radio Frequency Channel Number). The assignment
between channel numbers N and carrier center frequencies F is defined as:
The tables in this section provide an overview of all supported FDD and TDD operating
bands. For each band they list F
Offset
, N
Offset
, channel numbers N and carrier center fre-
quencies F. For frequencies above 3.3 GHz, option R&S CMW-KB036 is required.
The table for FDD uplink signals lists also the separation between uplink carrier fre-
quency and downlink carrier frequency (frequency pair for one UE in FDD mode).
In addition to the 3GPP defined bands listed in the tables, a user-defined operating
band is supported (option R&S CMW-KS525 required). It uses a 100-kHz channel ras-
ter like the 3GPP defined bands. The frequency range and the channel number range
are configurable for uplink and downlink. For configuration see
Table 2-12: Operating bands for FDD uplink signals
FDD
Band
F
Offset, UL
[MHz]
N
Offset, UL
Channel No N
UL
F
UL
[MHz]
F
DL
-F
UL
[MHz]
1
1920
18000
18000 to 18599
1920 to 1979.9
190
2
1850
18600
18600 to 19199
1850 to 1909.9
80
3
1710
19200
19200 to 19949
1710 to 1784.9
95
4
1710
19950
19950 to 20399
1710 to 1754.9
400
5
824
20400
20400 to 20649
824 to 848.9
45
6
830
20650
20650 to 20749
830 to 839.9
45
7
2500
20750
20750 to 21449
2500 to 2569.9
120
8
880
21450
21450 to 21799
880 to 914.9
45
9
1749.9
21800
21800 to 22149
1749.9 to 1784.8
95
10
1710
22150
22150 to 22749
1710 to 1769.9
400
11
1427.9
22750
22750 to 22949
1427.9 to 1447.8
48
12
699
23010
23010 to 23179
699 to 715.9
30
13
777
23180
23180 to 23279
777 to 786.9
-31
General Description