LTE Multi Evaluation Measurement
R&S
®
CMW-KM5xx/-KS5xx
530
User Manual 1173.9628.02 ─ 16
Fig. 3-32: LTE Multi Evaluation: Power Monitor
Each subframe power value is RMS averaged over the entire subframe, excluding 20
μs at each subframe border.
The number of subframes to be captured and shown on the X-axis is configurable as
well as the offset of subframe 0 relative to the trigger event, see
The power monitor can be used for power control tests, especially for aggregate power
control tests (see 3GPP TS 36.521, 6.3.5 "Power Control").
For the parameters at the bottom, see
chapter 3.2.6.14, "Common View Elements"
For query of the diagram contents via remote control, see
3.2.6.10
Detailed Views: Power Dynamics
The power dynamics view shows a diagram and a statistical overview of related power
results. For signals with carrier aggregation, only the configured "Measurement Car-
rier" is measured.
The following figure shows measurement results for the general ON/OFF time mask.
General Description
深圳德标仪器