![R&S CMW-KM5 Series Скачать руководство пользователя страница 356](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802356.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
356
User Manual 1173.9628.02 ─ 16
Return values:
<Enable>
OFF | ON
*RST:
OFF
Example:
See
Configuring UL Power Control for Call Setup
Usage:
Query only
Firmware/Software:
V3.2.20
Manual operation:
See
"Toggle P0-UE-PUSCH at RRC Setup"
CONFigure:LTE:SIGN<i>:UL:APPower:RSPower:ADVanced
<RefSignalPower>
Specifies the "referenceSignalPower" value, signaled to the UE if advanced UL power
configuration applies.
Parameters:
<RefSignalPower>
Range:
-60 dBm to 50 dBm
*RST:
18 dBm
Default unit: dBm
Example:
See
Configuring UL Power Control for Call Setup
Firmware/Software:
V3.0.50
Manual operation:
See
CONFigure:LTE:SIGN<i>:UL:APPower:PIRPower:ADVanced
<TargetPower>
Specifies the "preambleInitialReceivedTargetPower" value, signaled to the UE if
advanced UL power configuration applies.
Parameters:
<TargetPower>
Range:
-120 dBm to -90 dBm
Increment: 2 dB
*RST:
-104 dBm
Default unit: dBm
Example:
See
Configuring UL Power Control for Call Setup
Firmware/Software:
V3.0.50
Manual operation:
See
"Preamble Initial Received Target Power"
CONFigure:LTE:SIGN<i>:UL:APPower:PNPusch:ADVanced
<P0NominalPUSCH>
Specifies the "p0-NominalPUSCH" value, signaled to the UE if advanced UL power
configuration applies.
Parameters:
<P0NominalPUSCH> Range:
-126 dBm to 24 dBm
*RST:
-85 dBm
Default unit: dBm
Command Reference