![R&S CMW-KM5 Series Скачать руководство пользователя страница 355](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802355.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
355
User Manual 1173.9628.02 ─ 16
Return values:
<TargetPower>
Range:
-120 dBm to -90 dBm
Default unit: dBm
Example:
See
Configuring UL Power Control for Call Setup
Usage:
Query only
Firmware/Software:
V3.0.50
Manual operation:
See
"Preamble Initial Received Target Power"
SENSe:LTE:SIGN<i>:UL:APPower:PNPusch:BASic?
Queries the "p0-NominalPUSCH" value, signaled to the UE if basic UL power configu-
ration applies.
Return values:
<P0NominalPUSCH> Range:
-126 dBm to 24 dBm
Default unit: dBm
Example:
See
Configuring UL Power Control for Call Setup
Usage:
Query only
Firmware/Software:
V3.0.50
Manual operation:
See
SENSe:LTE:SIGN<i>:UL:APPower:PCALpha:BASic?
Queries the value of parameter "alpha", signaled to the UE if basic UL power configu-
ration applies.
Return values:
<PathCompAlpha>
ZERO | DOT4 | DOT5 | DOT6 | DOT7 | DOT8 | DOT9 | ONE
ZERO
: 0
DOT4 ... DOT9
: 0.4 ... 0.9
ONE
: 1.0
Example:
See
Configuring UL Power Control for Call Setup
Usage:
Query only
Firmware/Software:
V3.0.50
Manual operation:
See
SENSe:LTE:SIGN<i>:UL:APPower:TPRRcsetup:BASic?
Queries the state of P0-UE-PUSCH toggling, determining the P0-UE-PUSCH values
signaled to the UE during RRC connection setup if basic UL power configuration
applies.
Command Reference