![R&S CMW-KM5 Series Скачать руководство пользователя страница 151](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802151.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
151
User Manual 1173.9628.02 ─ 16
LTE
For an LTE (E-UTRA) neighbor cell entry you can specify the operating band and
downlink channel number, the physical layer cell ID and the "QOffset".
Parameter "QOffset" corresponds to the value "q-OffsetCell" in 3GPP TS 36.331,
which equals "Qoffset
s,n
" in 3GPP TS 36.304. It is used by the UE when evaluating
candidates for cell reselection or triggering conditions for measurement reporting.
If the channel number of an entry and the currently used channel number are identical,
the parameters are written into system information block 4 (intra-frequency cell rese-
lection). Otherwise they are written into system information block 5 (inter-frequency cell
reselection).
Reselection thresholds defined for LTE are only relevant for system information block
5.
The list supports up to 16 active neighbor cell entries. The active entries can use up to
five different channel numbers. Active entries with the same channel number must
have different cell IDs.
Remote command:
GSM
For a GSM (GERAN) neighbor cell entry you can specify the operating band and the
channel number used for the Broadcast Control Channel (BCCH).
This information and the GSM reselection thresholds are written into system informa-
tion block 7.
Remote command:
WCDMA FDD
For a WCDMA (UTRA FDD) neighbor cell entry you can specify the operating band,
the downlink channel number and the primary scrambling code of the cell.
The channel number and the WCDMA reselection thresholds are written into system
information block 6.
Remote command:
CDMA2000, 1xEV-DO
For a CDMA2000 (1xRTT) or 1xEV-DO (HRPD) neighbor cell entry you can specify the
band class, the channel number and the physical cell ID which identifies the PN offset.
This information and the reselection thresholds, are written into system information
block 8 - the CDMA2000 parameters into element "parameters1XRTT", the 1xEV-DO
parameters into element "parametersHRPD".
Remote command:
GUI Reference