Remote command:
SCC Activation Mode
This setting is only displayed on the SCC tab. It configures the activation mode of the
SCC for carrier aggregation scenarios.
Option R&S CMW-KS512 is required for the modes "Manual" and "Semiautomatic".
See also
"Auto"
The SCC is activated automatically at UE attach, so that the state
"MAC Activated" is reached.
Prerequisite for this mode: The PCC RRC connection must be kept
after attach (
must be enabled). Otherwise the
"Auto" mode is identical to the "Semiautomatic" mode.
"Semiauto-
matic"
The SCC activation must be initiated manually once. As a result, all
state transitions required to reach the state "MAC Activated" are per-
formed.
This mode is useful if you want to establish first a PCC connection
and add the SCC connection later on after some tests.