![R&S CMW-KM5 Series Скачать руководство пользователя страница 114](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802114.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
114
User Manual 1173.9628.02 ─ 16
Connect ← Connect (hotkey)
If at least one default bearer has been established (UE is attached), you can use the
"Connect" section to configure a dedicated bearer. Press the "Connect" button to
establish a dedicated bearer with the configured settings.
"Default Bearer ID" selects the default bearer, to which the dedicated bearer shall be
mapped. For more details about the ID, see
"Profile" selects a dedicated bearer profile. The profiles contain optimum bearer set-
tings for voice calls, video calls and data connections with RLC acknowledged or unac-
knowledged mode.
"TFT Port Range" selects the ports for which traffic shall be routed to the dedicated
bearer. If you set up several dedicated bearers, the port ranges of the bearers must not
overlap.
In total, up to eight bearers can be established in parallel (default plus dedicated bear-
ers).
Remote command:
Disconnect ← Connect (hotkey)
Use the "Disconnect" section to release an established dedicated bearer.
Select the bearer via the "Dedicated Bearer ID" list. Then press the "Disconnect" but-
ton.
For more details about the ID, see
Remote command:
Inter/Intra-RAT (hotkey)
The hotkey opens a dialog for selection and configuration of the handover destination
and initiation of the handover.
The LTE signaling application supports a handover within the signaling application, e.g.
to another operating band, as well as a handover to another instrument or to another
signaling application. The two signaling applications must use different RF paths. If
they use the same RF path, an error message is displayed, indicating that blind hand-
over is not supported.
GUI Reference