<OLPLimit>
Open loop power tolerance value
Range:
0 dB to 15 dB
*RST:
10 dB
Default unit: dB
Example:
See
Firmware/Software:
V3.0.20
Manual operation:
See
CONFigure:WCDMa:MEAS<i>:PRACh:LIMit:PCONtrol:OFFPower
<Limit>
Defines an upper OFF power limit. Also enables or disables the limit check.
Parameters:
<Limit>
Range:
-90 dBm to 53 dBm
*RST:
-55 dBm
Default unit: dBm
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
Example:
See
Firmware/Software:
V3.0.20
Manual operation:
See
CONFigure:WCDMa:MEAS<i>:PRACh:LIMit:PCONtrol:PSTep
<Enable>,
<PreamblePwrStep>, <PwrStepLimit>
Enables or disables the check of the preamble power step limits and specifies these
limits.
Parameters:
<Enable>
OFF | ON
Disables | enables the limit check
*RST:
ON
<PreamblePwrStep> Expected preamble power step size
Range:
0 dB to 15 dB
*RST:
2 dB
Default unit: dB
<PwrStepLimit>
Preamble power step tolerance value
Range:
0 dB to 15 dB
*RST:
2 dB
Default unit: dB
Example: