WCDMA TPC Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
825
User Manual 1173.9657.02 ─ 11
Example:
See
Specifying Basic Measurement Settings
Firmware/Software:
V3.0.30
Manual operation:
See
CONFigure:WCDMa:MEAS<i>:TPC:MPEDch:AEXecution
<Enable>
Enables or disables automatic execution of the TPC setup for combined signal path
measurements in "Max. Power E-DCH" mode.
Parameters:
<Enable>
OFF | ON
*RST:
ON
Example:
See
Specifying Basic Measurement Settings
Firmware/Software:
V3.0.30
Manual operation:
See
CONFigure:WCDMa:MEAS<i>:TPC:ULCM:AEXecution
<Enable>
Enables or disables automatic execution of the TPC setup for combined signal path
measurements in "UL Compressed Mode" mode.
Parameters:
<Enable>
OFF | ON
*RST:
ON
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V3.2.70
Manual operation:
See
CONFigure:WCDMa:MEAS<i>:TPC:ULCM:MLENgth
<MeasLength>
Query the number of slots measured in "UL Compressed Mode" mode. The value is
fixed.
It can only be determined while the "UL Compressed Mode" mode is active. In other
modes INV is returned.
Parameters:
<MeasLength>
Range:
60 slots
*RST:
INV
Default unit: slots
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V3.2.70
Manual operation:
See
Command Reference