WCDMA Multi Evaluation Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
731
User Manual 1173.9657.02 ─ 11
<13_UE Power>
User equipment power
Range:
-100 dBm to 55 dBm
Default unit: dBm
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.5.3
V3.2.10: increased number of segments
Options:
R&S CMW-KM012
FETCh:WCDMa:MEAS<i>:MEValuation:LIST:SEGMent<no>:UEPower:CURRent?
Returns the UE power vs. slot results for segment <no> in list mode.
Suffix:
<no>
.
1..1000
Return values:
<Reliability>
In list mode, a zero reliability indicator indicates that the results
in all measured segments are valid. A non-zero value indicates
that an error occurred in at least one of the measured segments.
<ReturnCode>
Reliability indicator for the segment. The meaning of the
returned values is the same as for the common reliability indica-
tor, see previous parameter.
<UEpower>
User equipment power, one value per slot. The list contains
results for the indicated segment <no>.
If another measurement has been enabled for a segment, but
the UE power vs. slot measurement is disabled, NCAP is
returned.
Range:
-100 dBm to 55 dBm
Default unit: dBm
Example:
See
Usage:
Query only
Firmware/Software:
V3.2.60
Options:
R&S CMW-KM012
FETCh:WCDMa:MEAS<i>:MEValuation:LIST:SEGMent<no>:PHD:CURRent?
Returns the phase discontinuity vs. slot results for segment <no> in list mode.
Each value indicates the phase discontinuity at the boundary between the slot and the
previous slot. If the slot or the previous slot is not measured, NCAP is returned.
Suffix:
<no>
.
1..1000