WCDMA Multi Evaluation Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
724
User Manual 1173.9657.02 ─ 11
Usage:
Query only
Firmware/Software:
V1.0.15.0
V3.2.60: command renamed (
CARRier<c>
added)
Options:
R&S CMW-KM405 for dual carrier HSUPA
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
3.5.3.30
CD Monitor Results (Single Values)
The following commands return the PCDE results of the code domain monitor mea-
surement, measured in the preselected slot (see
FETCh:WCDMa:MEAS<i>:MEValuation:PCDE:CURRent?
FETCh:WCDMa:MEAS<i>:MEValuation:PCDE:MAXimum?
READ:WCDMa:MEAS<i>:MEValuation:PCDE:CURRent?
READ:WCDMa:MEAS<i>:MEValuation:PCDE:MAXimum?
Returns the Peak Code Domain Error (PCDE) results. In addition to the current PCDE
value the maximum PCDE value can be retrieved.
See also
chapter 3.2.6.7, "Detailed Views: CD Monitor"
Return values:
<Reliability>
<PCDError>
Peak code domain error
Range:
-100 dB to 0 dB
Default unit: dB
<PCDErrorPhase>
IPHase | QPHase
Phase where the peak code domain error was measured
IPHase
: I-Signal
QPHase
: Q-Signal
<PCDErrorCodeNo> Code number for which the PCDE was measured
Range:
0 to 255
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.2.7
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
3.5.3.31
RX Results (Single Values)
The following commands return the results of the RX measurements.
Command Reference
深圳德标仪器