WCDMA Multi Evaluation Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
717
User Manual 1173.9657.02 ─ 11
Usage:
Query only
Firmware/Software:
V1.0.10.1
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
FETCh:WCDMa:MEAS<i>:MEValuation:CARRier<c>:MODulation:CURRent?
FETCh:WCDMa:MEAS<i>:MEValuation:CARRier<c>:MODulation:AVERage?
FETCh:WCDMa:MEAS<i>:MEValuation:CARRier<c>:MODulation:MAXimum?
FETCh:WCDMa:MEAS<i>:MEValuation:CARRier<c>:MODulation:SDEViation?
READ:WCDMa:MEAS<i>:MEValuation:CARRier<c>:MODulation:CURRent?
READ:WCDMa:MEAS<i>:MEValuation:CARRier<c>:MODulation:AVERage?
READ:WCDMa:MEAS<i>:MEValuation:CARRier<c>:MODulation:MAXimum?
READ:WCDMa:MEAS<i>:MEValuation:CARRier<c>:MODulation:SDEViation?
CALCulate:WCDMa:MEAS<i>:MEValuation:CARRier<c>:MODulation:CURRent?
CALCulate:WCDMa:MEAS<i>:MEValuation:CARRier<c>:MODulation:AVERage?
CALCulate:WCDMa:MEAS<i>:MEValuation:CARRier<c>:MODulation:MAXimum?
CALCulate:WCDMa:MEAS<i>:MEValuation:CARRier<c>:MODulation:
SDEViation?
Return the current, average, maximum and standard deviation single value results.
The return values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each of the
first 14 results listed below. The TX time alignment is only returned by
FETCh
and
READ
commands.
The ranges indicated below apply to all results except standard deviation results. The
minimum for standard deviation results equals 0. The maximum equals the width of the
indicated range divided by two. Exceptions are explicitly stated.
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
Suffix:
<c>
.
1..2
Selects the carrier to be queried - only relevant for dual carrier
HSUPA
Return values:
<1_Reliability>
<2_EVMrms>
<3_EVMpeak>
Error vector magnitude RMS and peak value
Range:
0 % to 100 %
Default unit: %
<4_MagErrorRMS>
Magnitude error RMS value
Range:
0 % to 100 %
Default unit: %
Command Reference
深圳德标仪器