WCDMA Multi Evaluation Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
691
User Manual 1173.9657.02 ─ 11
<Value1> ...
<Value297/327>
These values correspond to test points that are separated by 30
kHz. The covered frequency ranges are:
Left section, line H mode B/C: -12450 kHz to -3570 kHz/-2670
kHz from the carrier
Right section, line H mode B/C: 3570 kHz/2670 kHz to 12450
kHz from the carrier
Line H mode A is not used for 100 kHz traces (NCAPs returned)
Range:
-100 dB to 0 dB
Default unit: dB
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.10.1
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
FETCh:WCDMa:MEAS<i>:MEValuation:TRACe:EMASk:KFILter:CURRent?
FETCh:WCDMa:MEAS<i>:MEValuation:TRACe:EMASk:KFILter:AVERage?
FETCh:WCDMa:MEAS<i>:MEValuation:TRACe:EMASk:KFILter:MAXimum?
READ:WCDMa:MEAS<i>:MEValuation:TRACe:EMASk:KFILter:CURRent?
READ:WCDMa:MEAS<i>:MEValuation:TRACe:EMASk:KFILter:AVERage?
READ:WCDMa:MEAS<i>:MEValuation:TRACe:EMASk:KFILter:MAXimum?
Returns the values of the spectrum emission 30 kHz traces. The results of the current,
average and maximum traces can be retrieved.
See also
chapter 3.2.6.9, "Detailed Views: Spectrum Emission Mask"
Return values:
<Reliability>
<Value1> ...
<Value1665>
These values correspond to test points that are separated by 15
kHz and cover the frequency range between -12480 kHz and
12480 kHz from the carrier.
Range:
-100 dB to 0 dB
Default unit: dB
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.10.1
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
3.5.3.21
CDP vs Slot Results (Traces)
The following commands return the code domain power (CDP) vs. slot trace results of
the multi evaluation measurement.
Command Reference