WCDMA Multi Evaluation Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
608
User Manual 1173.9657.02 ─ 11
// select a measurement length of 30 slots (2 WCDMA frames)
// *****************************************************************************
CONFigure:WCDMa:MEAS:MEValuation:SCOunt:SPECtrum 30
// *****************************************************************************
// Specify BER settings:
// select a measurement length of 30 slots (2 WCDMA frames)
// *****************************************************************************
CONFigure:WCDMa:MEAS:MEValuation:SCOunt:BER 30
3.4.1.4
Configuring the Trigger System
// *****************************************************************************
// Set trigger source, timeout, trigger level, slope, delay
// and minimum trigger gap.
// *****************************************************************************
TRIGger:WCDMa:MEAS:MEValuation:SOURce 'IF Power'
TRIGger:WCDMa:MEAS:MEValuation:TOUT 1
TRIGger:WCDMa:MEAS:MEValuation:THReshold -30
TRIGger:WCDMa:MEAS:MEValuation:SLOPe FEDGe
TRIGger:WCDMa:MEAS:MEValuation:DELay 0.001
TRIGger:WCDMa:MEAS:MEValuation:MGAP 0.00002
3.4.1.5
Specifying Limits
// *****************************************************************************
// Define all modulation limits
// *****************************************************************************
CONFigure:WCDMa:MEAS:MEValuation:LIMit:MERRor 20, OFF
CONFigure:WCDMa:MEAS:MEValuation:LIMit:EVMagnitude 20, 40
CONFigure:WCDMa:MEAS:MEValuation:LIMit:PERRor 20, OFF
CONFigure:WCDMa:MEAS:MEValuation:LIMit:PHD ON, 70, 40
CONFigure:WCDMa:MEAS:MEValuation:LIMit:PHSDpcch ON, 5.5, 20, 40
CONFigure:WCDMa:MEAS:MEValuation:LIMit:IQOFfset -20
CONFigure:WCDMa:MEAS:MEValuation:LIMit:IQIMbalance ON
CONFigure:WCDMa:MEAS:MEValuation:LIMit:CFERror 150
// *****************************************************************************
// Define relative CDE limits and specify the uplink channel configuration
// *****************************************************************************
CONFigure:WCDMa:MEAS:MEV:LIMit:RCDerror:ECDP -20,-30,-15,-36,-25,-30,-17,-43
CONFigure:WCDMa:MEAS:MEValuation:LIMit:RCDerror:EECDp:DPCCh ON,4,256
CONFigure:WCDMa:MEAS:MEValuation:LIMit:RCDerror:EECDp:DPDCh ON,14,64
CONFigure:WCDMa:MEAS:MEValuation:LIMit:RCDerror:EECDp:HSDPcch:CONFig ACK
CONFigure:WCDMa:MEAS:MEValuation:LIMit:RCDerror:EECDp:HSDPcch ON,50,256
CONFigure:WCDMa:MEAS:MEValuation:LIMit:RCDerror:EECDp:EDPCch ON,20,256
CONFigure:WCDMa:MEAS:MEValuation:LIMit:RCDerror:EECDp:EDPDch2 ON,160,4
// *****************************************************************************
Programming
深圳德标仪器