WCDMA Signaling
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
158
User Manual 1173.9657.02 ─ 11
Option R&S CMW-KS410 is required for S-CPICH.
The DPCH level value and the F-DPCH level value are equal. While the CPC feature is
active the F-DPCH is activated automatically and is displayed in the code domain dia-
gram instead of the DL DPCH, see
chapter 2.4.9.6, "Code Domain Diagram"
Option R&S CMW-KS413 is required for F-DPCH.
For background information see
chapter 2.2.10.6, "Power Levels"
Remote command:
etc.
etc.
Code ← Channel Table
Defines the channelization code number of a channel. Some channels are never chan-
nelized (e.g. S-SCH), so no channel code is displayed. Gray values indicate fixed
standardized channelization codes. They cannot be modified but are relevant for dis-
play of code conflicts.
For background information see
chapter 2.2.10.4, "Channelization Codes"
Option R&S CMW-KS410 is required for S-CPICH.
Remote command:
etc.
etc.
Symbol Rate ← Channel Table
Displays the symbol rate of a channel. For most channels this value is fixed. For the
DPCH it depends on the connection configuration (e.g. connection type, data rate, ...).
Option R&S CMW-KS410 is required for S-CPICH.
Remote command:
n/a
P-CPICH Enhanced > Signalized Level
Defines the P-CPICH power level to be reported to the UE. The UE determines the
path loss by comparison of this power level and the power level measured on the pilot
bits of the P-CPICH. A larger path loss results in a larger initial preamble power.
Remote command:
S-CPICH Enhanced
Option R&S CMW-KS410 is required.
2nd Scrambling Code ← S-CPICH Enhanced
Defines index k used for calculation of a secondary scrambling code number by adding
k to the primary scrambling code number (see
GUI Reference