Remote control commands
R&S
®
AREG800A
323
User Manual 1179.3615.02 ─ 01
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:AREGenerator:DLOGging:NINFo?
Queries the number of info messages within the logged data.
Return values:
<DynLoggNumOfInf> integer
Range:
0 to 100
*RST:
0
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:AREGenerator:DLOGging:NWARning?
Queries the number of warnings within the logged data.
Return values:
<DynLoggNumOfWar>integer
Range:
0 to 100
*RST:
0
Usage:
Query only
Manual operation:
See
11.15.6
Measurement setup commands
Example: Configuring TRX frontends
// Set an air gap of 50 cm between TRX frontend and target.
SOURce1:AREGenerator:FRONtend:TRX1:OTA:OFFSet 0.5
SOURce1:AREGenerator:RADar:ANTenna:CUSTom:STATe 1
SOURce1:AREGenerator:RADar:ANTenna:REG:GAIN:TX 20
SOURce1:AREGenerator:RADar:ANTenna:REG:GAIN:RX 15
SOURce1:AREGenerator:RADar:OTA:OFFSet 0.5
SOURce1:AREGenerator:RADar:DBYPass:STATe 0
SOURce1:AREGenerator:RADar:POWer:INDicator?
// Response: "GOOD"
Example: Configuring QAT frontends
// Set an air gap of 50 cm between QAT frontend and target.
SOURce1:AREGenerator:FRONtend:QAT1:OTA:OFFSet 0.5