R&S XU 4200
Local Control (Local Mode)
6166.5368.02.01 3.52
RX CBIT STATUS
Meaning
of entries
R X C B I T S t a t u s
1 0 2 N O G O E
2 0 1 P S U F A N W
2 0 3 P S U T E M P W
4 0 7 I F O V E R L O A D W
4 1 0 S Y N T H U N L O C K E
Fig. 3.39
RX CBIT STATUS.
Display text (error code)
Status
Description
RX CBIT Status
–
Menu name
102 NOGO
ERROR
General fault in the radio; at least one CBIT error
message is active
201 PSU FAN
WARNING
Rotation speed of the power supply unit fan too low
203 PSU TEMP
WARNING
Temperature exceeded on the PSU Board
407 IF OVERLOAD
WARNING
Signal overload in intermediate frequency section
410 SYNTH UNLOCK
ERROR
PLL synthesizer unlocked in the receiver module
Note:
See chapter 4.2 Troubleshooting for the detailed CBIT event
descriptions.