![R&S 1444.1190K02 Скачать руководство пользователя страница 137](http://html1.mh-extra.com/html/rands/1444-1190k02/1444-1190k02_user-manual_774881137.webp)
Remote control basics
R&S
®
NRPxxP
137
User Manual 1179.5760.02 ─ 02
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
Sensor waiting for trigger
0
0
0
0
0
0
0
0
0
0
0
0
0
0
+
Figure 10-10: Operation trigger status register
Querying the register:
●
STATus:OPERation:TRIGger:CONDition?
●
STATus:OPERation:TRIGger[:SUMMary][:EVENt]?
Table 10-12: Used operation trigger status bits and their meaning
Bit no.
Short description
Bit is set if
1
Sensor waiting for trigger
Power sensor is waiting for a trigger event. When the trigger
event occurs, the power sensor changes into the measuring
state.
10.2.5.4
Operation sense status register
The
CONDition
register contains information whether a power sensor is being initial-
ized. The
EVENt
register contains information whether an initialization was started or
completed since the last query.
A power sensor is initialized if:
●
Supply voltage is switched on (power-up).
●
Power sensor was connected.
●
Reset was performed using:
–
–
Status reporting system