Remote Control Commands
R&S
®
NRX
336
User Manual 1178.5566.02 ─ 07
Manual operation:
See
CALCulate<Measurement>[:CHANnel<Channel>]:TRACe:AVERage[:STATe]
<value>
Effective for trace measurements.
Enables or disables the averaging filter. If enabled, the number of measured values is
averaged. Averaging reduces the effect of noise so that more reliable results are
obtained.
Suffix:
<Measurement>
.
1 to 8
Measurement
<Channel>
1 to 2
1 = primary sensor, 2 = secondary sensor
Parameters:
<value>
*RST:
ON
Manual operation:
See
CALCulate<Measurement>[:CHANnel<Channel>][:POWer]:NCORrection[:STATe]
<state>
Effective for R&S
frequency selective power sensors.
Enables or disables the noise cancellation.
Suffix:
<Measurement>
.
1 to 8
Measurement
<Channel>
1 to 2
1 = primary sensor, 2 = secondary sensor
Parameters:
<state>
*RST:
OFF
CALCulate<Measurement>[:CHANnel<Channel>][:POWer]:VBWidth:ENUM
<value>
Requires a wideband power sensor.
Sets the video filter bandwidth. Reducing the video bandwidth also increases the trig-
ger sensitivity.
Suffix:
<Measurement>
.
1 to 8
Measurement
Configuring Sensors
www.allice.de