GUI reference
R&S
®
ZNA
651
User Manual 1178.6462.02 ─ 20
Timer Settings
This button group allows you to define how the firmware calculates the "hardware set-
tling wait times" in the current channel.
"Auto" (default) Let the firmware choose the suitable algorithm, based on the chan-
nel's current measurement task
"MonoFre-
quent"/"Freq-
Convert-
ing"/"Slow"
Manually (and statically) select one of the "hardware settling wait
time" calculation algorithms
Remote command:
5.14
Offset Embed softtool
The "Offset Embed" softtool allows you to define a length offset and loss for each test
port. The offset compensates for the known length and loss of (non-dispersive and per-
fectly matched) transmission lines between the calibrated reference plane and the
DUT. It also contains advanced functions for deembedding/embedding the DUT from/
into more general physical/virtual (matching) networks placed between the calibrated
reference plane and the DUT.
Access:
Channel – [Offset
Embed]
Background information
Refer to
Chapter 4.6, "Offset parameters and de-/embedding"
5.14.1
Offset Embed dock widget
On activating a tab in the "Offset Embed" softtool, a dock widget is displayed beneath
the trace area, whose content pane is synchronized with the selected softtool tab.
Access:
Channel – [Offset
Embed]
5.14.1.1
Overview panel
Shows an overview of the overall calculation flow and provides quick access to the
"Offset Embed" functions.
Access:
Channel – [Offset
Embed] > "Overview"
Offset Embed softtool