GUI reference
R&S
®
ZNA
503
User Manual 1178.6462.02 ─ 20
Optional Columns
Each selected (checked) option adds a column to the segment list and the point list.
●
"Name" allows you to assign a name to each segment. A segment name is a string
that is allowed to contain letters, numbers and special characters.
●
"Power (Pb)" allows you to define the internal source power (channel base power)
for each individual sweep segment. See
If checked, you have the possibility to define port-specific power levels by selecting
the related ports in the "Advanced Ports (Pb) Power" table. Unselected ports are
driven with the segment-specific power.
●
"Meas Bandwidth" defines the IF filter bandwidth for each individual sweep seg-
ment. See
●
"Selectivity" defines the selectivity of the IF filter used for each sweep segment.
See
●
"LO < > RF" allows you to define segment-specific "Image Suppr." settings; see
●
"Segment Bits" enables the definition of a segment-dependent 4-bit binary value to
control four independent output signals at the User Port connector (lines 16, 17,
18, 19; see
on page 1644). The output signals are
3.3 V TTL signals which can be used to differentiate between up to 16 independent
analyzer states.
For an application example, refer to the detailed remote control description
(
OUTPut<Ch>:UPORt:SEGMent<Seg>[:VALue]
Setting the segment bits does not change the analyzer state.
●
"Time" defines the sweep time for each segment. The default configuration for a
new segment is equal to the sweep time setting for unsegmented sweeps; see
Sweep Softtool